Dwyer | Mercoid | WE Anderson | Flotect

Dwyer Series DPG

Series DPG Digital Pressure Gage

±0.25% or ±0.5% F.S. Accuracy, NEMA 4X (IP66) Aluminum Housing

Replace your outdated analog gages with the new Dwyer Series DPG Digital Pressure Gage. The Series DPG has a high ±0.25% or ±0.5% full scale accuracy. The 4 digit digital display will reduce the potential for errors in readings by eliminating parallax error commonly produced with analog gages.

Series DPG is battery powered and has an auto-shut off to conserve battery life. Battery life, on average, will last 2000 hours. A 4 button key pad allows easy access to features without the need to work through complex menus or difficult key combinations. These features include backlight, peak and valley, tare or auto zero and conversion of the pressure units.

 

Specifications

  • Service: Compatible liquids and combustible gases (for FM listing see Agency Approvals below).
  • Wetted Materials: Type 316L SS.
  • Housing Materials: Polycarbonate front and back cover, anodized aluminum extruded housing with recessed grooves, polycarbonate overlay, Buna-N O-rings, 316L SS sensor construction.
  • Accuracy:DPG-000: 0.5% full scale; DPG-100: ±0.25% full scale; ±1 least significant digit @ 70°F (21°C) (includes linearity, hysteresis, repeatability).
  • Pressure Limit: 2x pressure range for models ≤1000 psi; 5000 psi for 3000 psi range; 7500 psi for 5000 psi range.
  • Enclosure Rating: Designed to meet NEMA 4/4X (IP66).
  • Temperature Limits: 0 to 130°F (-18 to 55°C).
  • Thermal Effect: Between 70 to 130°F is 0.016%/F. Between 32 to 70°F is 0.026%/F. Between 10 to 32°F is 0.09%/F. Between 0 to 10°F is 0.50%/F.Size:3.00″ OD x 1.90″ deep (max).
  • Process Connection: 1/4″ male NPT.
  • Weight: 8.84 oz (275 g).
  • Display: 4 digit (.425″ H x .234″ W digits).
  • Power Requirements:(2) AAA alkaline batteries, included, user replaceable.
  • Battery Life: 2000 hours typical; Low battery indicator.Auto Shut-Off:Gage: 60 minute auto shut-off. Auto shut-off may be disengaged. Backlight: 2 minute auto shut-off.
  • Agency Approvals: DPG-000: CE; DPG-100: CE, FM approved to be intrinsically safe for Class I, Division 1, Groups A, B, C and D, for ranges 0-15 and 0-3000 psi.

 

Available Models


±0.5% Accuracy

MODELDESCRIPTION
DPG-000selectable engineering units: -14.70-0 psi, -1.033 kg/cm², -1.013 bar, -29.93" Hg, -33.94 ft w.c., -101.4 kPa, -235.2 oz/in², -407.3" w.c., -1013 mbar, -1034 cm w.c., -760.7 mm Hg.
DPG-002selectable engineering units: 15.00 psi, 1.055 kg/cm², 1.034 bar, 30.54" Hg, 34.61 ft w.c., 103.4 kPa, 240 oz/in², 415.2" w.c., 1034 mbar, 1055 cm w.c., 775.7 mm Hg.
DPG-003selectable engineering units: 30.00 psi, 2.109 kg/cm², 2.069 bar, 61.08" Hg, 69.21 ft w.c., 206.9 kPa, 480 oz/in², 830.4" w.c., 2069 mbar, 2109 cm w.c., 1551 mm Hg.
DPG-004selectable engineering units: 50.00 psi, 3.515 kg/cm², 3.448 bar, 101.8" Hg, 115.4 ft w.c., 344.8 kPa, 800 oz/in², 1384" w.c., 3448 mbar, 3515 cm w.c., 2586 mm Hg.
DPG-005selectable engineering units: 100.0 psi, 7.03 kg/cm², 6.895 bar, 203.6" Hg, 230.7 ft w.c., 689.5 kPa, 1600 oz/in², 2768" w.c., 6895 mbar, 7031 cm w.c., 5172 mm Hg.
DPG-006selectable engineering units: 200.0 psi, 14.06 kg/cm², 13.79 bar, 407.2" Hg, 461.4 ft w.c., 1379 kPa, 3200 oz/in², 5536" w.c.
DPG-007selectable engineering units: 300.0 psi, 21.09 kg/cm², 20.69 bar, 610.8" Hg, 692.1 ft w.c., 2069 kPa, 4800 oz/in², 8304" w.c.
DPG-008selectable engineering units: 500.0 psi, 35.15 kg/cm², 34.48 bar, 1018" Hg, 1154 ft w.c., 3448 kPa, 8000 oz/in².
DPG-009selectable engineering units: 1000 psi, 70.3 kg/cm², 68.98 bar, 2036" Hg, 2307 ft w.c., 6895 kPa.
DPG-010selectable engineering units: 3000 psi, 210.9 kg/cm², 206.9 bar, 6108" Hg, 6921 ft w.c.
DPG-011selectable engineering units: 5000 psi, 351.5 kg/cm², 344.8 bar.
DPG-020range 30" Hg-0-15 psi.


±0.25% Accuracy

MODELDESCRIPTION
DPG-102selectable engineering units: 15.00 psi, 1.055 kg/cm², 1.034 bar, 30.54" Hg, 34.61 ft w.c., 103.4 kPa, 240 oz/in², 415.2" w.c., 1034 mbar, 1055 cm w.c., 775.7 mm Hg, CE and FM approved.
DPG-103selectable engineering units: 30.00 psi, 2.109 kg/cm², 2.069 bar, 61.08" Hg, 69.21 ft w.c., 206.9 kPa, 480 oz/in², 830.4" w.c., 2069 mbar, 2109 cm w.c., 1551 mm Hg, CE and FM approved.
DPG-104selectable engineering units: 50.00 psi, 3.515 kg/cm², 3.448 bar, 101.8" Hg, 115.4 ft w.c., 344.8 kPa, 800 oz/in², 1384" w.c., 3448 mbar, 3515 cm w.c., 2586 mm Hg, CE and FM approved.
DPG-105selectable engineering units: 100.0 psi, 7.03 kg/cm², 6.895 bar, 203.6" Hg, 230.7 ft w.c., 689.5 kPa, 1600 oz/in², 2768" w.c., 6895 mbar, 7031 cm w.c., 5172 mm Hg, CE and FM approved.
DPG-106selectable engineering units: 200.0 psi, 14.06 kg/cm², 13.79 bar, 407.2" Hg, 461.4 ft w.c., 1379 kPa, 3200 oz/in², 5536" w.c., CE and FM approved.
DPG-107selectable engineering units: 300.0 psi, 21.09 kg/cm², 20.69 bar, 610.8" Hg, 692.1 ft w.c., 2069 kPa, 4800 oz/in², 8304" w.c., not CE and FM approved.
DPG-108selectable engineering units: 500.0 psi, 35.15 kg/cm², 34.48 bar, 1018" Hg, 1154 ft w.c., 3448 kPa, 8000 oz/in², CE and FM approved.
DPG-109selectable engineering units: 1000 psi, 70.3 kg/cm², 68.98 bar, 2036" Hg, 2307 ft w.c., 6895 kPa, CE and FM approved.
DPG-110selectable engineering units: 3000 psi, 210.9 kg/cm², 206.9 bar, 6108" Hg, 6921 ft w.c., CE and FM approved
DPG-111selectable engineering units: 5000 psi, 351.5 kg/cm², 344.8 bar, not CE and FM approved.