Dwyer | Mercoid | WE Anderson | Flotect

Duotect H3 Pressure Switch

Duotect H3 Pressure Switch

Duotect H3 Pressure Switch
Duotect H3

Setpoints from 10″ w.c. to 200 psid – Rated 1500 psig, Weatherproof

The Duotect H3 Pressure Switch is a Explosion-proof, heavy duty, industrial unit that has a unique new design which provides sensitivity to differential pressures as low as 10 inches of water (254 mm w.c.), yet handles total pressure of 1500 psi (103 bar). Unlike common differential pressure switches that use a piston-type motion transfer, the Series H3 utilizes a rotary motion transfer shaft that prevents a change in total pressure from causing a setpoint shift. Unit yields deadbands approximately 5% of range, with zero setpoint shift due to variation in working pressures. Friction is minimized and repeatability increased by allowing range spring to act directly on diaphragm plate. Rolling diaphragm design maintains constant effective area to further reduce friction. Diaphragm is allowed to “seat”, allowing application of full rated pressure, up to 1500 psi (103 bar), on either high or low pressure port, without damage. Special over-travel feature prevents overtightening of range adjust screw. Choose optional 316SS chamber for water and water-based fluids or harsher applications.

Duotect Series H3Duotect H3 Specifications

  • Wetted Materials: See Ordering page.
  • Temperature Limit:-4 to 220°F (-20 to 104°C). ATEX: -4 to 194°F (-20 to 90°C).
  • Pressure Limit: 1500 psig (103 bar).
  • Enclosure Rating:Standard meets NEMA 4X (IP56); Drain option meets NEMA 3 (IP54). For hazardous use see “Hazardous Location Ratings Chart” on Catalog page.
  • Switch Type: SPDT or DPDT snap switch.Electrical Rating:5A @ 125/250 VAC, 30 VDC.
  • Electrical Connections: See Ordering page.
  • Conduit Connection: 3/4″ female NPT.
  • Process Connection: 1/8″ female NPT.
  • Mounting Orientation: Vertical.
  • Set Point Adjustment: Internal screw.
  • Weight: 4 lb 2 oz (2 kg).
  • Deadband: Approximately 5% of range.
  • Agency Approvals: ATEX (see “Ratings Chart” on catalog page), CE, CSA, UL.

 

MODELCHAMBERDIAPHRAGMADJ OPER RANGECIRCUIT 5A @ 125/250 VAC, 30 VDC
H3A-1SL AluminumNitrile10-180 in. w.c. (2.48-44.78 kPa)SPDT snap action rated
H3A-1DL AluminumNitrile10-180 in. w.c. (2.48-44.78 kPa)DPDT snap action rated
H3A-2SL AluminumNitrile 0.5-15 psid (0.3-1 bar)SPDT snap action rated
H3A-2DL AluminumNitrile 0.5-15 psid (0.3-1 bar)DPDT snap action rated
H3A-3SL AluminumNitrile 5-70 psid (.34-4.8 bar)SPDT snap action rated
H3A-3DL AluminumNitrile 5-70 psid (.34-4.8 bar)DPDT snap action rated
H3A-4SL AluminumNitrile10-200 psid (.7-13.8 bar)SPDT snap action rated
H3A-4DL AluminumNitrile10-200 psid (.7-13.8 bar)DPDT snap action rated
H3S-1SL316 SS Viton10-180 in. w.c. (2.48-44.78 kPa)SPDT snap action rated
H3S-1DL316 SS Viton10-180 in. w.c. (2.48-44.78 kPa)DPDT snap action rated
H3S-2SL316 SS Viton 0.5-15 psid (0.3-1 bar)SPDT snap action rated
H3S-2DL316 SS Viton 0.5-15 psid (0.3-1 bar)DPDT snap action rated
H3S-3SL316 SS Viton 5-70 psid (.34-4.8 bar)SPDT snap action rated
H3S-3DL316 SS Viton 5-70 psid (.34-4.8 bar)DPDT snap action rated
H3S-4SL316 SS Viton10-200 psid (.7-13.8 bar)SPDT snap action rated
H3S-4DL316 SS Viton10-200 psid (.7-13.8 bar)DPDT snap action rated