Dwyer | Mercoid | WE Anderson | Flotect

Dwyer Series 610

Series 610 Low Differential Pressure Transmitter

Ideal for Clean Rooms, Easy to Field Calibrate with Security Key

The Dwyer Series 610 Low Differential Pressure Transmitters are capable of measuring the pressures and flow of air or non-conducting gases at high resolutions. Designed specifically for clean rooms, isolation rooms, and other critical environments, the Series 610 is ideal for situations when accurate and reliable pressure monitoring is essential. Easy access pressure ports and electrical connections, removable process heads, and detachable terminal blocks make for fast and easy installation. The Series 610 transmitters are available for air pressure ranges as low as 0.1 in w.c. full-scale. The Series 610 transmitters can be ordered as either ±0.25% or ±0.5% FS accuracy, base mount or din rail mount and the option of a digital read out display. In addition, a calibration key can be ordered that allows the user to set zero and span. One key will work on multiple transmitters.

 

Dwyer Series 610 Specifications

  • Service:Air or similar non-conducting gases.
  • Accuracy:±0.25% or ±0.5% F.S.
  • Stability:±0.5%/yr.
  • Temperature Limits:-20 to 160°F (-29 to 71°C).
  • Pressure Limits:2 psi (0.137 bar).
  • Thermal Effect:0.5% FS.
  • Power Requirements:13.5 to 30 VDC.
  • Output:4 to 20 mA.
  • Loop Resistance:800 ohms max.
  • Current Consumption:25 mA.
  • Zero and Span Adjustments:External security key pendant.
  • Response Time:0.02 to 0.04 seconds.
  • Electrical Connections:Detachable screw terminal connector.
  • Process Connections:3/16″ O.D. barbed brass fittings on removable process head.
  • Enclosure Rating:Fire retardant ABS.
  • Mounting Orientation:Vertical.
  • Weight:9 oz (255 g).
  • Agency Approvals:CE.

 

Available Models


Base Mount - 0.25% Accuracy - With Display

MODELDESCRIPTION
610-00C-BDVLow differential pressure transmitter, range ±.05" w.c.
610-01A-BDVLow differential pressure transmitter, range 0 to 1" w.c.
610-01B-BDVLow differential pressure transmitter, range ±1" w.c.
610-01C-BDVLow differential pressure transmitter, range ±.1" w.c.
610-01D-BDVLow differential pressure transmitter, range 0 to .1" w.c.
610-05A-BDVLow differential pressure transmitter, range 0 to 5" w.c.
610-05B-BDVLow differential pressure transmitter, range ±5" w.c.
610-05C-BDVLow differential pressure transmitter, range ±0.5" w.c.
610-05D-BDVLow differential pressure transmitter, range 0 to .5" w.c.
610-10A-BDVLow differential pressure transmitter, range 0 to 10" w.c.
610-25A-BDVLow differential pressure transmitter, range 0 to 2.5" w.c.
610-25B-BDVLow differential pressure transmitter, range ±2.5" w.c.
610-25C-BDVLow differential pressure transmitter, range ±.25" w.c.
610-25D-BDVLow differential pressure transmitter, range 0 to .25" w.c.


Base Mount - 0.25% Accuracy - Without Display

MODELDESCRIPTION
610-00C-BNVLow differential pressure transmitter, range ±.05" w.c.
610-01A-BNVLow differential pressure transmitter, range 0 to 1" w.c.
610-01B-BNVLow differential pressure transmitter, range ±1" w.c.
610-01C-BNVLow differential pressure transmitter, range ±.1" w.c.
610-01D-BNVLow differential pressure transmitter, range 0 to .1" w.c.
610-05A-BNVLow differential pressure transmitter, range 0 to 5" w.c.
610-05B-BNVLow differential pressure transmitter, range ±5" w.c.
610-05C-BNVLow differential pressure transmitter, range ±0.5" w.c.
610-05D-BNVLow differential pressure transmitter, range 0 to .5" w.c.
610-10A-BNVLow differential pressure transmitter, range 0 to 10" w.c.
610-25A-BNVLow differential pressure transmitter, range 0 to 2.5" w.c.
610-25B-BNVLow differential pressure transmitter, range ±2.5" w.c.
610-25C-BNVLow differential pressure transmitter, range ±.25" w.c.
610-25D-BNVLow differential pressure transmitter, range 0 to .25" w.c.


Base Mount - 0.50% Accuracy - With Display

MODELDESCRIPTION
610-00C-BDELow differential pressure transmitter, range ±.05" w.c.
610-01A-BDELow differential pressure transmitter, range 0 to 1" w.c.
610-01B-BDELow differential pressure transmitter, range ±1" w.c.
610-01C-BDELow differential pressure transmitter, range ±.1" w.c.
610-01D-BDELow differential pressure transmitter, range 0 to .1" w.c.
610-05A-BDELow differential pressure transmitter, range 0 to 5" w.c.
610-05B-BDELow differential pressure transmitter, range ±5" w.c.
610-05C-BDELow differential pressure transmitter, range ±0.5" w.c.
610-05D-BDELow differential pressure transmitter, range 0 to .5" w.c.
610-10A-BDELow differential pressure transmitter, range 0 to 10" w.c.
610-25A-BDELow differential pressure transmitter, range 0 to 2.5" w.c.
610-25B-BDELow differential pressure transmitter, range ±2.5" w.c.
610-25C-BDELow differential pressure transmitter, range ±.25" w.c.
610-25D-BDELow differential pressure transmitter, range 0 to .25" w.c.


Base Mount - 0.50% Accuracy - Without Display

MODELDESCRIPTION
610-00C-BNELow differential pressure transmitter, range ±.05" w.c.
610-01A-BNELow differential pressure transmitter, range 0 to 1" w.c.
610-01B-BNELow differential pressure transmitter, range ±1" w.c.
610-01C-BNELow differential pressure transmitter, range ±.1" w.c.
610-01D-BNELow differential pressure transmitter, range 0 to .1" w.c.
610-05A-BNELow differential pressure transmitter, range 0 to 5" w.c.
610-05B-BNELow differential pressure transmitter, range ±5" w.c.
610-05C-BNELow differential pressure transmitter, range ±0.5" w.c.
610-05D-BNELow differential pressure transmitter, range 0 to .5" w.c.
610-10A-BNELow differential pressure transmitter, range 0 to 10" w.c.
610-25A-BNELow differential pressure transmitter, range 0 to 2.5" w.c.
610-25B-BNELow differential pressure transmitter, range ±2.5" w.c.
610-25C-BNELow differential pressure transmitter, range ±.25" w.c.
610-25D-BNELow differential pressure transmitter, range 0 to .25" w.c.


DIN Rail Mount - 0.25% Accuracy - With Display

MODELDESCRIPTION
610-00C-DDVLow differential pressure transmitter, range ±.05" w.c.
610-01A-DDVLow differential pressure transmitter, range 0 to 1" w.c.
610-01B-DDVLow differential pressure transmitter, range ±1" w.c.
610-01C-DDVLow differential pressure transmitter, range ±.1" w.c.
610-01D-DDVLow differential pressure transmitter, range 0 to .1" w.c.
610-05A-DDVLow differential pressure transmitter, range 0 to 5" w.c.
610-05B-DDVLow differential pressure transmitter, range ±5" w.c.
610-05C-DDVLow differential pressure transmitter, range ±0.5" w.c.
610-05D-DDVLow differential pressure transmitter, range 0 to .5" w.c.
610-10A-DDVLow differential pressure transmitter, range 0 to 10" w.c.
610-25A-DDVLow differential pressure transmitter, range 0 to 2.5" w.c.
610-25B-DDVLow differential pressure transmitter, range ±2.5" w.c.
610-25C-DDVLow differential pressure transmitter, range ±.25" w.c.
610-25D-DDVLow differential pressure transmitter, range 0 to .25" w.c.


DIN Rail Mount - 0.25% Accuracy - Without Display

MODELDESCRIPTION
610-00C-DNVLow differential pressure transmitter, range ±.05" w.c.
610-01A-DNVLow differential pressure transmitter, range 0 to 1" w.c.
610-01B-DNVLow differential pressure transmitter, range ±1" w.c.
610-01C-DNVLow differential pressure transmitter, range ±.1" w.c.
610-01D-DNVLow differential pressure transmitter, range 0 to .1" w.c.
610-05A-DNVLow differential pressure transmitter, range 0 to 5" w.c.
610-05B-DNVLow differential pressure transmitter, range ±5" w.c.
610-05C-DNVLow differential pressure transmitter, range ±0.5" w.c.
610-05D-DNVLow differential pressure transmitter, range 0 to .5" w.c.
610-10A-DNVLow differential pressure transmitter, range 0 to 10" w.c.
610-25A-DNVLow differential pressure transmitter, range 0 to 2.5" w.c.
610-25B-DNVLow differential pressure transmitter, range ±2.5" w.c.
610-25C-DNVLow differential pressure transmitter, range ±.25" w.c.
610-25D-DNVLow differential pressure transmitter, range 0 to .25" w.c.


DIN Rail Mount - 0.50% Accuracy - With Display

MODELDESCRIPTION
610-00C-DDELow differential pressure transmitter, range ±.05" w.c.
610-01A-DDELow differential pressure transmitter, range 0 to 1" w.c.
610-01B-DDELow differential pressure transmitter, range ±1" w.c.
610-01C-DDELow differential pressure transmitter, range ±.1" w.c.
610-01D-DDELow differential pressure transmitter, range 0 to .1" w.c.
610-05A-DDELow differential pressure transmitter, range 0 to 5" w.c.
610-05B-DDELow differential pressure transmitter, range ±5" w.c.
610-05C-DDELow differential pressure transmitter, range ±0.5" w.c.
610-05D-DDELow differential pressure transmitter, range 0 to .5" w.c.
610-10A-DDELow differential pressure transmitter, range 0 to 10" w.c.
610-25A-DDELow differential pressure transmitter, range 0 to 2.5" w.c.
610-25B-DDELow differential pressure transmitter, range ±2.5" w.c.
610-25C-DDELow differential pressure transmitter, range ±.25" w.c.
610-25D-DDELow differential pressure transmitter, range 0 to .25" w.c.


DIN Rail Mount - 0.50% Accuracy - Without Display

MODELDESCRIPTION
610-00C-DNELow differential pressure transmitter, range ±.05" w.c.
610-01A-DNELow differential pressure transmitter, range 0 to 1" w.c.
610-01B-DNELow differential pressure transmitter, range ±1" w.c.
610-01C-DNELow differential pressure transmitter, range ±.1" w.c.
610-01D-DNELow differential pressure transmitter, range 0 to .1" w.c.
610-05A-DNELow differential pressure transmitter, range 0 to 5" w.c.
610-05B-DNELow differential pressure transmitter, range ±5" w.c.
610-05C-DNELow differential pressure transmitter, range ±0.5" w.c.
610-05D-DNELow differential pressure transmitter, range 0 to .5" w.c.
610-10A-DNELow differential pressure transmitter, range 0 to 10" w.c.
610-25A-DNELow differential pressure transmitter, range 0 to 2.5" w.c.
610-25B-DNELow differential pressure transmitter, range ±2.5" w.c.
610-25C-DNELow differential pressure transmitter, range ±.25" w.c.
610-25D-DNELow differential pressure transmitter, range 0 to .25" w.c.