Series 626 & 628 Industrial Pressure Transmitter
Complete Offering of Ranges, Connections and Outputs
The Dwyer Series 626 Pressure Transmitters possess a highly precise 0.25% full scale accuracy piezo-resistive sensor contained in a compact, rugged, NEMA 4X stainless steel general purpose housing or cast aluminum conduit housing.
The Dwyer Series 628 Pressure Transmitters are ideal for OEM’s with 1% full scale accuracy sensors. The transmitter is also available in the general purpose stainless steel housing and the cast aluminum conduit housing.
The corrosion resistant 316L stainless steel wetted parts allow the Series 626 and 628 transmitters to measure the pressure in a multitude of processes from hydraulic oils to chemicals. The Series 626 and 628 are available in absolute and pressure ranges with a variety of optional outputs, process connections and electrical terminations to allow you to select the right transmitter for your application.
Common Applications
- Compressors
- Pumping Systems
- Irrigation System Pressure
- Fire Pump Control Pressure
- Industrial Process Monitoring
- Refrigerant Line Pressures on Air Handlers when used with optional Refrigerant Valve Depressor
- Trash Compaction Equipment
Series 626 & 628 Specifications
- Service: Compatible gases and liquids.
- Wetted Materials: Type 316L SS.
- Accuracy:>626: 0.25% FS; 0.20% RSS;
628: 1.0% FS; 0.5% RSS;
626 Absolute Ranges: 0.5% FS; 0.35% RSS.
(Includes linearity, hysteresis, and repeatability). - Temperature Limit: 0 to 200°F (-18 to 93°C).
- Compensated Temperature Range: 0 to 175°F (-18 to 79°C).
- Thermal Effect: ±0.02% FS/°F. (includes zero and span).
- Pressure Limits: See Catalog page.
- Power Requirements: 10-30 VDC (for 4-20 mA, 0-5, 1-5, 1-6 VDC outputs); 13-30 VDC (for 0-10, 2-10 VDC outputs); 5 VDC ±0.5 VDC (for 0.5-4.5 VDC ratio-metric output).
- Output Signal: 4-20 mA, 0-5 VDC,1-5 VDC, 0-10 VDC, or 0.5-4.5 VDC.
- Response Time: 300 ms.
- Loop Resistance: 0-1000 Ohms max. R max = 50 (Vps-10) Ohms (4-20 mA output), 5K Ohms (0-5, 1-5, 1-6, 0-10, 2-10, 0.5-4.5 VDC output).
- Stability:1.0% FS/year (Typ.).
- Current Consumption:38 mA maximum (for 4-20 mA output); 10 mA maximum (for 0-5, 1-5, 1-6, 0-10, 2-10, 0.5-4.5 VDC output); 140 mA maximum (for all 626/628/629-CH with optional LED).
- Electrical Connections: Conduit Housing (-CH): terminal block; 1/2″ female NPT conduit. General Purpose Housing (-GH): cable or DIN EN175801-803-C.
- Process Connection: 1/4″ male or female NPT and BSPT.
- Enclosure Rating: NEMA 4X (IP66).
- Mounting Orientation: Mount in any position.
- Weight:10 oz (283 g).
- Agency Approvals: CE.
Series 626 & 628 Features
- Metal Conduit Housing Option
- Robust 316L SS Oil Filled Sensor
- Compact Design
Available Models
MODEL | DESCRIPTION |
---|---|
628-00-CH-P1-E5-S1 | range 0-15 psia, max. pressure 30 psig, over pressure 45 psig. |
628-07-CH-P1-E5-S1 | range 0-15 psig, max. pressure 30 psig, over pressure 150 psig. |
628-08-CH-P1-E5-S1 | range 0-30 psig, max. pressure 60 psig, over pressure 300 psig. |
628-09-CH-P1-E5-S1 | range 0-50 psig, max. pressure 100 psig, over pressure 300 psig. |
628-10-CH-P1-E5-S1 | range 0-100 psig, max. pressure 200 psig, over pressure 500 psig. |
628-12-CH-P1-E5-S1 | range 0-200 psig, max. pressure 400 psig, over pressure 1000 psig. |
628-13-CH-P1-E5-S1 | range 0-300 psig, max. pressure 600 psig, over pressure 1500 psig. |
628-14-CH-P1-E5-S1 | range 0-500 psig, max. pressure 1000 psig, over pressure 2500 psig. |
MODEL | DESCRIPTION |
---|---|
626-08-GH-P1-E4-S7 | .25% FS, 30 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
626-10-GH-P1-E4-S7 | .25% FS, 100 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
626-12-GH-P1-E4-S7 | .25% FS, 200 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
626-13-GH-P1-E4-S7 | .25% FS, 300 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
626-14-GH-P1-E4-S7 | .25% FS, 500 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
626-15-GH-P1-E4-S7 | .25% FS, 1000 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
626-18-GH-P1-E4-S7 | .25% FS, 3000 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
626-19-GH-P1-E4-S7 | .25% FS, 5000 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
MODEL | DESCRIPTION |
---|---|
628-08-GH-P1-E4-S7 | .25% FS, 30 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
628-10-GH-P1-E4-S7 | .25% FS, 100 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
628-12-GH-P1-E4-S7 | .25% FS, 200 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
628-13-GH-P1-E4-S7 | .25% FS, 300 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
628-14-GH-P1-E4-S7 | .25% FS, 500 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
628-15-GH-P1-E4-S7 | .25% FS, 1000 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
628-18-GH-P1-E4-S7 | .25% FS, 3000 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |
628-19-GH-P1-E4-S7 | .25% FS, 5000 psig, general purpose, 1/4" male NPT, .5-4.5 VDC output. |