Piezoresistive submersible transmitters for wastewater, ground water, wells, boreholes, and sewage lift stations. Lightning protected and intrinsically safe options available.

Perfect for Sludge and Slurries

Perfect for Ground Water and Wells

Miniature — Only 0.63″ Diameter

Flush Tip — Non-Clogging Design
| Feature | PBLT2 / PBLTX | SBLT2 / SBLTX | MBLT | FBLT |
|---|---|---|---|---|
| Best Application | Wastewater, slurries | Ground water, wells | Wells, boreholes | Sewage, lift stations |
| Accuracy | ±0.25% FS | ±0.25% FS | ±0.10% or ±0.25% FS | ±0.25% FS |
| Diameter | Standard | Slim | 0.63″ miniature | Narrow |
| Diaphragm | Large 316 SS | Bullet nose 316 SS | 316 SS nose cap | Flush PTFE-coated FKM |
| Lightning Protection | Yes (PBLT2) | Yes (SBLT2) | Yes (standard) | Yes (standard) |
| Intrinsically Safe | PBLTX model | SBLTX model | No | No |
| Output | 4–20 mA | 4–20 mA | 4–20 mA or 0–5V | 4–20 mA |
| Power | 13–30 VDC | 13–30 VDC | 8–33 VDC | 10–33 VDC |
| Agency Approvals | PBLTX: CE, cULus | SBLTX: CE, cULus | CE | CE |
Need help selecting the right submersible transmitter?
Our team can match the right series to your application, media, and installation requirements.